#04390 (15KW AIR)
#04722
(15KW LIQUID)

• Quiet, powerful Generac OHVI single-cylinder or V-Twin engines fueled by natural gas or LP gas.

• UL Listed remote-mounted pre-wired automatic transfer switch with 8, 10 or 12 circuit emergency load center for fast and efficient unattended transfer to generator when utility power fails.

• A standard weather protective enclosure with sound-absorbing panels protects generator from harmful weather and also reduces exterior noise levels. Includes key locks for security.

• Hinged top and removable front panel for easy serviceability.

• Built-in charger maintains battery at optimum performance level.

• Automatic safety shutdowns protect engine and generator in event of low oil pressure, high temperature, overspeed and/or overcrank.

• Automatic seven-day exerciser runs the system for twelve minutes weekly to maintain top running condition.

• Installation system includes the pre-wired automatic transfer switch with built-in load center, 30' and 2' wiring harnesses, pre-wired external connection box, 1' flexible fuel line, "Do-It-Yourself" installation guide and a composite mounting pad.

AIR/LIQUID Cooled Generac Guardian Home Standby Generators
~ 2 Year Warranty
~

Call for Pricing & Availability

Models #04390 #04722
Rated Power LP (kW) 15* 15
Rated Power NG (kW) 13 15

Automatic Transfer Switch
100 Amp NEMA 1 NOT INCLUDED
Frequency 60Hz 60Hz
Voltage 120/240V
Single Phase
120/240V
Single Phase
Amps @ 120/240V
Single phase NG
108.3/54.2 125/62.5
Engine Alternator RPM 3600/3600 1800/1800
Engine 992cc
30 HP GENERAC OHVI V-Twin
1.5L OHC
GENERAC
4 Cylinder
Fuel NG or LPG NG or LPG
Engine Cooling Air Liquid
Dimensions(L”x W"x H”) 48 x 24 x 28.25 68 x 30 x 40
Unit Weight (LBS) 487

*To operate @ 15,000 watt requires kit #04578-0 (No Charge)
960


Call for specific custom configuration of your equipment and pricing on additional products.
 816-931-3009 [ 9-6pm CST M-F ]